Product introduction:
The tabletop photocatalytic cracking fluidized bed reactor includes: reaction system, gas feed system, liquid feed system, preheating system, reaction product separation, collection and analysis system, control system, etc. The reaction tube is equipped with a high-pressure visual window to introduce the light source into the catalyst bed.
Product features:
1. Tubular reactor
·The inner wall of the pipe is equipped with a quartz glass sleeve.
·The upper end of the reaction tube is equipped with a high-pressure circular visual window.
·Built in thermowells and thermocouples to detect the temperature in the reactor tube in real time.
·The reaction tube adopts gasket seal structure, which is easy to disassemble and clean.

2. Split heating furnace
·The heating furnace is a three-stage temperature control, and the outer wall plug-in thermocouple is used to detect the temperature of the kettle wall in real time.
·The wall temperature is associated with the furnace and can be switched between automatic and manual.
·Split design, safety buckle fastening, convenient for switching.
3. Safety valve
The safety pressure can be set. If it exceeds this pressure, it will be automatically discharged.
4. Pressure gauge, pressure sensor
Real time detection shows preheating and reaction pipeline pressure.
5. Thermal insulation tracing band
The temperature can be set, and the temperature of the control pipeline can be detected in real time.

6. Control system
·Industrial touch screen with process flow chart on the interface
·Set and display the temperature values of preheating section, constant temperature section and holding section of reactor heating furnace.
·The internal temperature of the reactor can be displayed.
·The pressure inside the reactor can be displayed.
·The preheater can set the preheating furnace temperature value and display it.
·The temperature value can be set and displayed for heat tracing of each pipeline.
·The gas flowmeter can set and display the flow rate, and display the cumulative flow value.
·The liquid metering pump can set and display the flow rate and the cumulative metering value; It can control the opening and closing of the metering pump.
·The above data can be collected, recorded and exported to excel.
·The control system and alarm safety system operate independently to effectively ensure the safety of the experiment.
·The alarm function can set the temperature and pressure alarm values, and automatically cut off the heating power after triggering the alarm.